BSIDE-O9 Handheld dual-channel oscilloscope
- Hign-concerned Chemical: None
- IS Battery Demountable: No
- Record Length: 128Kbyte
- Model Number:Ô9/O7
- Certification: CE
- Origin: Mainland China
- Real Time Sampling Rate: 250MSa/s
- Brand Name: BSIDE
- Display Size: 3.0 – 4.9 Inches
- Display resolution: 480*320Pixels
- DIY Supplies: ELECTRICAL
- Band Width: 50MHz
- Digital Channels: 2
Multimeter Function Comparison |
||||||||
Model |
O7 |
O9 |
||||||
Function |
Range |
Resolution |
Range |
Resolution |
||||
DC Voltage(V) Accuracy |
1000V 0.001V |
1000V 0.0001V |
||||||
DC Voltage(mV) Accuracy |
600mV 0.01mV ±(1.0%+5) |
200mV 0.01mV |
||||||
AC Voltage (V) Accuracy |
750V 0.001V ±(1.0%+3) |
750V 0.0001V |
||||||
AC Voltage (mV) Accuracy |
600mV 0.001mV ±(1.2%+5) |
200mV 0.001mV ±(1.2%+5) |
||||||
DC Current(mA) Accuracy |
600mA 0.01mA |
200mA 0.01mA ±(1.0%+3) |
||||||
AC Current(mA) Accuracy |
600mA 0.01mA ±(1.2%+5) |
200mA 0.01mA |
||||||
AC Current(A) |
6000A(Need Flexible Current Clamp) |
2000A(Need Flexible Current Clamp) |
||||||
Resistance Accuracy |
60MΩ 0.001MΩ |
200MΩ 0.0001MΩ |
||||||
Capacitance |
99.99mF 0.001mF |
99.999mF 0.001mF |
||||||
Temperature |
-20~1000℃ |
-20~1000℃ |
||||||
Display Value |
6000 Counts |
20000 Counts |
||||||
Diode |
√ |
Connectivity |
√ |
|||||
True Virtual Value |
√ |
Screen Backlight |
√ |
|||||
Low Battery Reminder |
√ |
Auto Power-off |
√ |
|||||
Size |
216.6*84.5*36mm |
Weight |
384g |
|||||
Type Of Battery |
18650 Battery 3000mA*2,6000mA Long Endurance |
|||||||
Screen |
3.98-inch TFT full-view color screen |
|||||||
Oscilloscope technical index comparison |
||||
Character |
Instructions |
|||
Bandwidth |
O9:50MHz |
Dual channel real-time sampling |
||
O7:25MHz |
||||
Sampling |
Sampling mode |
Real-time sampling |
||
Sampling rate |
O9:250MSa/s |
|||
Channel |
2 |
Dual channel DC, AC |
||
INPUT |
Input coupling |
DC/AC |
||
Input impedance |
1MΩ,@16pf |
|||
Probe attenuatior |
×1,×10 |
|||
Maximum input voltage |
X1 range <150V, |
|||
Horizontal |
Sampling rate rang |
O7 |
O9 |
|
Waveform interpolation |
(sinx)x |
|||
Sweep range |
100ns/div-20s/div |
|||
Time base accuracy |
20ppm |
|||
Storage depth |
128Kbyte |
|||
Vertical |
Sensitivity |
20mV/div-10V/div |
||
Displacement range |
4 squares (plus or minus) |
|||
Analog bandwidth |
O7:25MHZ |
O9:50MHZ |
||
Frequency response |
>10HZ |
|||
Rise time |
<10ns |
|||
DC gain accuracy |
± 3 % |
|||
Measure |
Automatic |
Period, Frequency, Peak-to-Peakvalue, Maximum value, Minimum value, Duty cycle, Root meansquare |
||
Trigger |
Trigger mode |
Auto, Normal, Single |
||
Trigger edge |
Rising edge, Falling edge |
|||
Display mode |
YT, XY, RoII |
|||
Afterglow time |
Minimum, 500ms, 1S, 10S, Unlimited |
|||
Waveform Type |
Sine wave, Square wave,Triangular wave, Half wave,Full wave, Sawtooth wave, DC |
|||
Frequency Range |
Sine wave: 0HZ-5MHZ; Square wave, triangular wave, half wave, full wave, sawtooth wave, DC: 0HZ-2MHZ |
|||
Channel |
1 |
|||
Output Amplitude |
0.1V~3.0V |
|||
Resolution |
1HZ |
|||
Square-wave Duty Cycle |
1%~99% |
Oscilloscope Mode Main Screen Description |
||||||
No. |
Name |
Instructions |
No. |
Name |
Instructions |
|
1 |
Trigger channel |
CH1 is channel 1, and CH2 is channel 2 |
14 |
Vertical flip-flop |
Vertical voltage position triggered |
|
2 |
Running status |
Status: Stop/Run |
15 |
Horizontal trigger |
Horizontal timebase position of the trigger |
|
3 |
Ch1 |
CH1 waveform is displayed in yellow |
16 |
CH1 Parameters |
Specific parameters of CH1 |
|
4 |
Ch2 |
CH2 waveform is displayed in blue |
17 |
CH2 Parameters |
Specific parameters of CH2 |
|
5 |
Channel switch |
CH1/CH2 On-off state |
18 |
Voltage/Time base menu |
Press up key to increase the voltage amplitude, Adjustable range: Press letf key left to enlarge the time base, Adjustable range: |
|
6 |
Attenuation |
Channel attenuation factor |
||||
7 |
Voltage scale |
Vertical voltage scale value |
||||
8 |
Time base |
Timebase position in storage depth |
||||
9 |
Time base scale |
Horizontal time base scale value |
19 |
Wave movement |
Press the up/down button to adjust theupper and lower positions of the waveform, |
|
10 |
Wave Mode |
Auto/Normal/Single |
||||
11 |
Trigger mode |
Rising or falling edge |
20 |
Trigger cursor |
Press the up and dow keys to adjustthe position of the trigger cursor |
|
12 |
Battery level |
Battery status and charging status |
21 |
Measuring cursor |
Press F4 to switch the measurement cursorselection, |
|
13 |
Trigger level |
Trigger voltage value |
||||
Multimeter Mode |
||||||
No. |
Name |
Instructions |
No. |
Name |
Instructions |
|
1 |
Battery level |
Displays the battery status and charging status |
8 |
Auto shutdown |
Displays the time to set automatic shutdown |
|
2 |
Main display |
Display multimeter measurements, |
9 |
Peak mode |
Press PAEK switch to peak mode(this mode is only valid for AC voltage) |
|
3 |
Mode |
Measurement mode |
||||
4 |
Range |
Current mode range |
10 |
Maximum value |
Displays the maximum read value |
|
5 |
Auto range |
Automatic range switching |
11 |
Minimum value |
Displays the minimum read value |
|
6 |
HOLD |
Press SAVE key to pause the data display |
12 |
Average value |
Displays the average value |
|
7 |
Mode |
Display the current selected measurementmode is highlighted red.Press the left, right.up, and down arrow keys to switch gears |
13 |
Terminal prompt |
Displays the terminal to be selected for current mode |
|
14 |
Unit |
Displays the unit of the measured data |
Specification:
- Maximum display: 20000 count screen
- Size: 3.9 inches
- Bandwidth: 50MHz
- Real-time scanning rate: 250MSa/s
- Input impedance: 1MΩ
- Maximum Input Voltage: ×1 Range<150V, ×10 Range<300V (DC+AC Peak)
- Horizontal seconds range: 100ns/div -20s/div
- Vertical sensitivity: 20mV/div -10V/div
- DC voltage: 20mV 0.001mV ± (1%+5); 200mV/2V/20V 0.01mV/0.0001V/0.001V/ ±(0.8%+3); 200V/1000V 0.01V/0.1V ±(1%+5)
- AC voltage: 20mV 0.001mV ± (1.2%+5); 200mV/2V/20V 0.01mV/0.0001V/0.001V/ ±(1%+3); 200V 0.01V ±(1.2%+5); 750V 0.1V ±(1.2%+5)
- DC current: 20mA/200mA 0.001mA/0.01mA ±(1%+3)
- AC Current: 20mA/200mA 0.001mA/0.01mA ±(1.2%+5)
- Flexible Current Clamp AC Current: 200A/2000A 0.1A/1A ±(1%+5)
- Resistance: 200Ω 0.01Ω ± (1.2%+5); 2K Ω/20K Ω/200K Ω 0.0001K Ω/0.001K Ω/0.01KΩ ±(1.0% + 3); 2MΩ 0.0001MΩ ±(1.2% + 5); 20MΩ 0.001MΩ ±(1.5% + 5); 200MΩ 0.01MΩ ±(1.5% + 5)
- Capacitance: 999.9nF 0.01 nF ± (5% + 20) 9.999 μF/999.9 μF 0.001 μF/0.01 μF ± (4.5% + 5); 99.99mF 0.001mF ±(5.0%+10)
- Temperature: -20~1000°C/-4~1832°F 1°C/1°F ±(2.5% + 5)
- Diode: Yes
- Continuity: Yes
- Power supply: 5000mA
- Size: 216.6×84.5x36mm
- Weight: 384g
Package includes:
1 x Handheld Oscilloscope Multimeter
1 x EVA suitcase
2 x oscilloscope probes
1 x Oscilloscope Accessory
1 x multimeter pen
1 x Crocodile Clip
1 x box
1 x charging cable
1 x Instruction Manual
1 x warranty card
1 x User Manual
Buy-this-product-on-Aliexpress
Đánh giá
Chưa có đánh giá nào.